Rơ le an toàn ESM-2H201 (Euchner 085620)
Housing material | |
Housing | Polyamide PA6.6 |
Weight | |
Net | 0,23 kg |
Ambient temperature | |
At UB = 24V AC | -15 … 40 °C |
At UB = 24V DC | -15 … 60 °C |
Degree of protection | IP20 |
Mechanical life | |
operating cycles | 10 x 106 |
Contact material | AgSnO2 |
Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
Connection | Connection terminals |
Length of control cable | |
With conductor cross-section 0.75mm2 | 1000 m |
Safety contacts 13/14, 23/24 | |
Number of safety contacts | 2 |
Operating voltage | |
AC/DC | 24 V -10% … +10% |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | |
Leakage path/air gaps | 4 kV |
Overvoltage category according to IEC EN 60664-1 | 3 |
Reverse polarity protection | |
On version UB =24V DC | |
Connection rating | |
at 24V DC | 1,5 W |
Degree of contamination (external, according to EN 60947-1) | 2 |
Connection cross-section | 0,14 … 2,5 mm² |
Test voltage | |
Control system/contacts | 2,5 kV |
Control voltage | |
On S12-S13 and on S22 and S23 | 24 V |
Control current | |
Both push buttons | 40 mA 2x |
LED indicator | 2 status displays (green) for relays K1 and K2 |
Safety contacts 13/14, 23/24 | |
Type of output | |
NO | Relay contacts, floating and positively driven (redundant) |
Switching voltage | |
AC | max.250 V |
DC | max.24 V |
Switching current | min.20 mA at 24V |
Fusing | |
External contact fuses (safety circuit) according to IEC 60269-1 | 10A gG |
Utilization category acc. to EN 60947-5-1 | |
AC-15 | 3A, 250V |
DC-13 | 3A, 24V |
AC-12 | 6A ohmic load, 250V |
DC-12 | 6A ohmic load, 24V |
Breaking capacity according to UL | 6A 250V AC / 2A 24V DC |
Delay time | |
After operation of the push buttons | max.0,02 s Response delay time |
Release time | max.0,02 s |
Synchronization time | max.0,5 s |
In compliance with | EN 60947-5-1: 2004+A1: 2009; EN ISO 13849-1: 2015; EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015; EN 50581: 2012 (RoHS) |
Performance Level | PL e |
Category | 4 |
PFHD | 1.2 x 10-8 |
Number of switching cycles | |
≤ 3 A at 24 V DC | max.22500 1/Jahr |
≤ 1 A at 24 V DC | max.100000 1/Jahr |
≤ 0.1 A at 24 V DC | max.400000 1/Jahr |
Mission time | 20 y |